PROJECT DESCRIPTION
High power for the production of cold glycol solution with output from 50.000 F/h to 500.000 F/h.
– Cooling of the musts for the clarification before the fermentation.
– Automatic control of the fermentation temperatures.
– Tartaric stabilization of the wines.
– Conditioning of wine cellars and offices.
– Semi-hermetics pistons compressors working with ecological gas R507.
– Air condensation.
– Bundle pipes evaporator in stainless steel Aisi 316.
– Accumulation tank of the cold solution in stainless steel Aisi 304.
– Centrifuge pump for primary circulation.
– Centrifugal pumps for secondary circulation according to the customer demands.
– Possibility of more contemporarily uses to serve.
– Electronic control panel with box in stainless steel Aisi 304 in CE and IP 55 norm.
– Aisi 304 stainless steel panels and frame fixed.
– Possibility to connect various types of external heat exchangers to the units.
– Models with one, two or three compressors.
Optional:
– Possibility to mount hermetics compressors.
On request, it is possible to order cooling units with varying powers in base to the various demands.
Model - KC50
T. Evaporation: 5°c
T. Water: 10°c
Resa: 48720 F/h
Cooling circuit n°: 1
Model - KC80
T. Evaporation: 5°c
T. Water: 10°c
Resa: 83000 F/h
Cooling circuit n°: 1
Model - KC100
T. Evaporation: 5°c
T. Water: 10°c
Resa: 99760 F/h
Cooling circuit n°: 1
Model - KC150
T. Evaporation: 5°c
T. Water: 10°c
Resa: 150000 F/h
Cooling circuit n°: 1
Model - KC80 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 82000 F/h
Cooling circuit n°: 2
Model - KC100 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 100000 F/h
Cooling circuit n°: 2
Model - KC150 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 150000 F/h
Cooling circuit n°: 2
Model - KC200 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 205000 F/h
Cooling circuit n°: 2
Model - KC250 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 253000 F/h
Cooling circuit n°: 2
Model - KC300 2C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 300000 F/h
Cooling circuit n°: 2
Model - KC450 3C
T. Evaporation: 5°c
T. Water: 10°c
Resa: 450000 F/h
Cooling circuit n°: 3
Model - KC40 2C-E
T. Evaporation: 5°c
T. Water: 10°c
Resa: 44.720 F/h
Cooling circuit n°: 2
Model - KC50 2C-E
T. Evaporation: 5°c
T. Water: 10°c
Resa: 48720 F/h
Cooling circuit n°: 2
Model - KC80 2C-E
T. Evaporation: 5°c
T. Water: 10°c
Resa: 83000 F/h
Cooling circuit n°: 2
Model - KC100 4C-E
T. Evaporation: 5°c
T. Water: 10°c
Resa: 100000 F/h
Cooling circuit n°: 4
Model - KC150 4C-E
T. Evaporation: 5°c
T. Water: 10°c
Resa: 150000 F/h
Cooling circuit n°: 5
Data not binding. Enomet reserves him to change it without any notice.